Marine Cables | |||
MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
Power Distribution Cables
300V Twisted pairs shielded Type T/N signal cables
Construction
Conductor:
Stranded copper conductor tin or alloy coated where necessary for the application , conductor per ASTM or IEC
60228.
Separator tape: optional
Insulation:
Polyvinylchloride(PVC)/nylon according to IEEE 1580 2010 Type T/N,Type X, E, T, S, P, LSX and LSE as option.
Pairs:
Shielded:
Jacket: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or
TPO jacket as option (optional for Type P with HD thicknesses).
Armor: optional and shall be nonmagnetic
Sheath: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P
or TPO sheath as option (optional except for tinned copper braid armoured cables).
Optional: For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO
jacket/sheath.
Table B.16—Typical dimensions and weights; twisted-pair signal cable 300 V;Type T/N cables, shielded pairs
Number of pairs |
Conductor |
Unarmored |
Armored |
Armored and sheathed |
|||
Nom. dia. (in) |
Approx. weight (lb/1000 ft) |
Nom. dia. (in) |
Approx. weight (lb/1000 ft) |
Nom. dia. (in) | Approx. weight (lb/1000 ft) |
||
1 | 20 | 0.26 | 32 | 0.32 | 48 | 0.41 | 80 |
2 | 20 | 0.4 | 56 | 0.46 | 77 | 0.59 | 143 |
3 | 20 | 0.43 | 69 | 0.49 | 93 | 0.62 | 163 |
4 | 20 | 0.47 | 84 | 0.53 | 111 | 0.66 | 186 |
5 | 20 | 0.51 | 99 | 0.57 | 128 | 0.7 | 208 |
6 | 20 | 0.59 | 132 | 0.65 | 163 | 0.78 | 253 |
8 | 20 | 0.63 | 160 | 0.69 | 193 | 0.82 | 288 |
10 | 20 | 0.74 | 195 | 0.8 | 232 | 0.97 | 377 |
15 | 20 | 0.89 | 299 | 0.95 | 344 | 1.12 | 514 |
20 | 20 | 0.98 | 369 | 1.04 | 419 | 1.21 | 603 |
25 | 20 | 1.11 | 445 | 1.17 | 501 | 1.34 | 707 |
30 | 20 | 1.14 | 507 | 1.2 | 563 | 1.37 | 774 |
40 | 20 | 1.28 | 640 | 1.34 | 708 | 1.51 | 942 |
50 | 20 | 1.45 | 778 | 1.51 | 854 | 1.74 | 1214 |
60 | 20 | 1.54 | 903 | 1.6 | 983 | 1.83 | 1363 |
1 | 18 | 0.28 | 43 | 0.34 | 59 | 0.44 | 97 |
2 | 18 | 0.44 | 80 | 0.5 | 104 | 0.63 | 175 |
3 | 18 | 0.47 | 103 | 0.53 | 130 | 0.66 | 205 |
4 | 18 | 0.51 | 128 | 0.57 | 157 | 0.7 | 237 |
5 | 18 | 0.59 | 172 | 0.65 | 203 | 0.78 | 293 |
6 | 18 | 0.64 | 199 | 0.7 | 232 | 0.83 | 328 |
8 | 18 | 0.69 | 248 | 0.75 | 283 | 0.92 | 420 |
10 | 18 | 0.81 | 305 | 0.87 | 348 | 1.04 | 504 |
15 | 18 | 0.97 | 463 | 1.03 | 513 | 1.2 | 696 |
20 | 18 | 1.08 | 586 | 1.14 | 642 | 1.31 | 843 |
25 | 18 | 1.22 | 714 | 1.28 | 779 | 1.45 | 1003 |
30 | 18 | 1.26 | 827 | 1.32 | 895 | 1.49 | 1125 |
40 | 18 | 1.42 | 1062 | 1.48 | 1138 | 1.65 | 1394 |
50 | 18 | 1.6 | 1302 | 1.66 | 1385 | 1.89 | 1779 |
60 | 18 | 1.77 | 1634 | 1.83 | 1728 | 2.06 | 2159 |
1 | 16 | 0.33 | 54 | 0.39 | 72 | 0.48 | 110 |
2 | 16 | 0.51 | 100 | 0.57 | 129 | 0.7 | 209 |
3 | 16 | 0.58 | 147 | 0.64 | 178 | 0.77 | 266 |
4 | 16 | 0.63 | 181 | 0.69 | 214 | 0.82 | 309 |
5 | 16 | 0.69 | 216 | 0.75 | 251 | 0.92 | 388 |
6 | 16 | 0.75 | 252 | 0.81 | 289 | 0.98 | 436 |
8 | 16 | 0.82 | 315 | 0.88 | 358 | 1.05 | 516 |
10 | 16 | 1 | 428 | 1.06 | 478 | 1.23 | 666 |
15 | 16 | 1.15 | 589 | 1.21 | 648 | 1.38 | 860 |
20 | 16 | 1.27 | 748 | 1.33 | 816 | 1.5 | 1048 |
25 | 16 | 1.45 | 914 | 1.51 | 990 | 1.74 | 1350 |
30 | 16 | 1.5 | 1061 | 1.56 | 1139 | 1.79 | 1510 |
40 | 16 | 1.75 | 1471 | 1.81 | 1563 | 2.04 | 1990 |
50 | 16 | 1.98 | 1798 | 2.04 | 1904 | 2.27 | 2382 |
60 | 16 | 2.1 | 2101 | 2.16 | 2212 | 2.39 | 2716 |
NOTE—These values are for reference purposes only and should not be construed as requirements. Dimensions are based on the use of Class B conductors. Weights of armored constructions are based on aluminum braid armor. It is recommended that the user/specifier contact the manuf acturer for manufacturer specific values.